SLA/6PRG/4PRG/10-30DC/-3AO [DIN]
SLA Functional Safety Logic Solver and Alarm
Input Description: Six Programmable Inputs for 0-25mA, 0-10V, RTD, T/C, Ohms, mV
Output Description: Four Relay Outputs and Four Discrete Outputs
Power Description: 4-Wire, 10-30VDC
Options Description: Three Programmable Analog Outputs, any range between 0-20mA
Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails
HART Signal Pass-through Capability: Yes
For use in Safety Instrumented Systems (SIS): Yes
Communication Protocol: MODBUS/TCP, Web Server
Device Power: 4-Wire, 24VDC Line/Mains Powered
Input: Programmable: All Input Types
Number of Alarm/Relay Outputs: 1, 2, 3, 4, 8
Analog Output: Yes
Integral Display: Yes
Intrinsically-Safe Input Connections: No
Configuration/Setup: PC Configurable, Ethernet
Housing/Enclosure: DIN Rail Enclosure
RoHS Compliant: Yes
Additional Features: Alarm/Event Voting, Math/Logic, Redundant Inputs
|
SPA2/HLPRG/4PRG/U/-AO [DIN]
SPA2 Programmable Limit Alarm Trip
Input Description: Programmable, any range within 0-50mA or 0-10V
Output Description: Four Alarm Outputs
Power Description: Universal Power, 21.6-375Vdc or 90-260Vac
Options Description: Programmable Analog Output, any range between 0-20mA and 0-10V
Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails
For use in Safety Instrumented Systems (SIS): No
Device Power: Universal: 4-Wire 24DC/117VAC/230VAC Line/Mains Powered
Input: Programmable, Current or Voltage, 4-20mA, 0-10VDC, 1-5VDC
Number of Alarm/Relay Outputs: 1, 2, 3, 4
Analog Output: Yes
Integral Display: Yes
Intrinsically-Safe Input Connections: No
Configuration/Setup: PC Configurable, USB Cable, Face-plate
Configurable
Housing/Enclosure: DIN Rail Enclosure
Hazardous Area Certifications: Non-Incendive/Div. 2, Zone 2
RoHS Compliant: Yes
|
STA/TPRG/3PRG/U/-AO [DIN]
STA Functional Safety Limit Alarm Trip
Input Description: Programmable Input for RTD, T/C, Ohms, mV or Potentiometer
Output Description: Two Alarm Outputs, One Fault Relay
Power Description: Universal Power, 21.6-375Vdc or 90-260Vac
Options Description: Programmable Analog Output, any range between 0-20mA and 0-10V
Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails
For use in Safety Instrumented Systems (SIS): Yes
Device Power: Universal: 4-Wire 24DC/117VAC/230VAC Line/Mains Powered
Input: Programmable, RTD, T/C, mV, Ohms, Potentiometer
Number of Alarm/Relay Outputs: 1, 2, 3
Analog Output: Yes
Integral Display: Yes
Intrinsically-Safe Input Connections: No
Configuration/Setup: PC Configurable, USB Cable, Face-plate Configurable
Housing/Enclosure: DIN Rail Enclosure
Hazardous Area Certifications: Non-Incendive/Div. 2, Zone 2
RoHS Compliant: Yes
|
SLA/6PRG/4PRG/10-30DC [DIN]
SLA Functional Safety Logic Solver and Alarm
Input Description: Six Programmable Inputs for 0-25mA, 0-10V, RTD, T/C, Ohms
Output Description: Four Relay Outputs and Four Discrete Outputs
Power Description: 4-Wire, 10-30VDC
Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails
HART Signal Pass-through Capability: Yes For use in Safety Instrumented Systems (SIS): Yes
Communication Protocol: MODBUS/TCP, Web Server
Device Power: 4-Wire, 24VDC Line/Mains Powered
Input: Programmable: All Input Types
Number of Alarm/Relay Outputs: 1, 2, 3, 4, 8
Integral Display: Yes
Intrinsically-Safe Input Connections: No
Configuration/Setup: PC Configurable, Ethernet
Housing/Enclosure: DIN Rail Enclosure
RoHS Compliant: Yes
Additional Features: Alarm/Event Voting, Math/Logic, Redundant Inputs
|
SRM/CC/3RO/24DC [DIN]
SRM Safety Relay Module
Input Description: Contact Closure
Output Description: Three Relay Outputs Power Description: 4-Wire, 24VDC
Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails
For use in Safety Instrumented Systems (SIS): Yes Device Power: 4-Wire, 24VDC
Input: Contact Closure
Number of Alarm/Relay Outputs: 1, 2, 3
Analog Output: No
Integral Display: No
Intrinsically-Safe Input Connections: No
Configuration/Setup: Face-plate Configurable
Housing/Enclosure: DIN Rail Enclosure
RoHS Compliant: Yes
|
SPA2IS/HLPRG/4PRG/U/-AO [DIN]
SPA2IS Associated IS Programmable Limit Alarm Trip
Input Description: Programmable, any range within 0-50mA or 0-10V
Output Description: Four Alarm Outputs
Power Description: Universal Power, 21.6-375Vdc or 90-260Vac
Options Description: Programmable Analog Output, any range between 0-20mA and 0-10V
Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails
For use in Safety Instrumented Systems (SIS): No
Device Power: Universal: 4-Wire 24DC/117VAC/230VAC Line/Mains Powered
Input: Programmable, Current or Voltage, 4-20mA, 0-10VDC, 1-5VDC
Number of Alarm/Relay Outputs: 1, 2, 3, 4
Analog Output: Yes
Integral Display: Yes
Intrinsically-Safe Input Connections: Yes
Configuration/Setup: PC Configurable, USB Cable, Face-plate Configurable
Housing/Enclosure: DIN Rail Enclosure
Hazardous Area Certifications: Non-Incendive/Div. 2, Zone 2
RoHS Compliant: In Process
|
NCS EMM -MAA
NCS NET Concentrator System with Multipoint Analog Alarm
Input Description: Programmable: Current, Voltage, RTD, T/C, mV, Ohms, Potentiometer, Discrete/Digital Contact
Output Description: Eight Relay Outputs Power Description: 20-30DC
Options Description: -MAA Multipoint Analog Alarm
Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails
For use in Safety Instrumented Systems (SIS): No
Device Power: 24VDC
Input: Universal: All Input Types, Discrete/Digital Contact Number of Alarm/Relay Outputs: 8
Analog Output: No
Integral Display: No
Intrinsically-Safe Input Connections: No
Configuration/Setup: PC Configurable, Ethernet
Housing/Enclosure: DIN Rail
Hazardous Area Certifications: Non-Incendive/Div. 2, Zone 2
RoHS Compliant: Yes
|
ECA/4-20mA/DH1H1/24DC/-TX [DIN]
ECA Current and Voltage Limit Alarm Trip
Input Description: 4-20mA
Output Description: Field Configurable, set as Dual, High/High, Failsafe
Power Description: 4-Wire, 24VDC
Options Description: 24V transmitter excitation for powering a 2-wire transmitter
Housing Description: Universal DIN-style housing mounts on G-type and Top Hat DIN-rails
For use in Safety Instrumented Systems (SIS): No
Device Power: 4-Wire, 24VDC
Input: 4-20mA
Number of Alarm/Relay Outputs: 1, 2
Analog Output: No
Integral Display: No
Intrinsically-Safe Input Connections: No
Housing/Enclosure: DIN Rail Enclosure
RoHS Compliant: No
|
330R2/PRG/2PRG/HIACDC/-AO-TX [P]
330R2 1/8 DIN Process and Temperature Panel Meter & Alarm
Input Description: 0-20mA, 4-20mA, ±20mA, 0-5V, 1-5V, 0-10V, ±10V, TC & RTD
Output Description: Two Alarm Outputs, Analog Output
Power Description: 4-Wire, 85-265VAC or 90-265VDC
Options Description: Isolated analog output and 24V transmitter excitation for powering connected transmitter
Housing Description: 1/8 DIN Panel mount, corrosion resistant Nema 4X, IP65 faceplate
For use in Safety Instrumented Systems (SIS): No
Device Power: 4-Wire, 85-265VAC or 90-265VDC
Input: Programmable, Current, Voltage, RTD, Thermocouple
Number of Alarm/Relay Outputs: 1, 2
Analog Output: Yes
Integral Display: Yes
Intrinsically-Safe Input Connections: No
Configuration/Setup: PC Configurable, USB Cable, Face-plate Configurable
Housing/Enclosure: 1/8 DIN Panel mount, corrosion resistant Nema 4X, IP65 faceplate
|
330R2/PRG/2PRG/LOACDC/-AO [P]
330R2 1/8 DIN Process and Temperature Panel Meter & Alarm
Input Description: 0-20mA, 4-20mA, ±20mA, 0-5V, 1-5V, 0-10V, ±10V, TC & RTD
Output Description: Two Alarm Outputs, Analog Output
Power Description: 4-Wire, 12-24VAC or 12-36VDC
Options Description: Isolated analog output
Housing Description: 1/8 DIN Panel mount, corrosion resistant Nema 4X, IP65 faceplate
For use in Safety Instrumented Systems (SIS): No
Device Power: 4-Wire, 12-24VAC or 12-36VDC
Input: Programmable, Current, Voltage, RTD, Thermocouple
Number of Alarm/Relay Outputs: 1, 2
Analog Output: Yes
Integral Display: Yes
Intrinsically-Safe Input Connections: No
Configuration/Setup: PC Configurable, USB Cable, Face-plate Configurable
Housing/Enclosure: 1/8 DIN Panel mount, corrosion resistant Nema 4X, IP65 faceplate
RoHS Compliant: Yes
|